»PROLOOP LOSplus« for low-overspill applications in large rooms and halls
Types
Induction loop amplifier up to 1000m2Producer
Humantechnik GmbH, Im Worth 25, D-79576 Weil am RheinBrief description
As a ready-for use system for operating low-overspill systems in large rooms of up to 1,000 m², the induction loop amplifier PROLOOP LOSplus has all the required electronic equipment in one single casing.The high-performance amplifier has an Automatic Gain Control (AGC) that also guarantees steady sound with excellent speech reproduction even in challenging acoustic conditions. For sound quality control on the induction loop outputs A and B, the PROLOOP LOSplus has a monitoring output for headphones.
Recommended area covered by this driver
1000m2Accesories
all needed accesories are available at Humantecnik websiteOwn experiences, UNB experts, Equalizent experts, Racio experts
Before installation better consult supplier for configuration of componentsExperiences of UNB clients, Equalizent clients, Racio clients
More informations
https://www.audioropa.com/en/products/induction-loop-systems/proloop-losplus/Supplier for the Czech Republic, Austria and Slovenia
Widex Line spol. s r.o., Bohušovická 230/12, 190 00 Praha 9tel: 283 882 217
email: info@widex.cz.
Comparing with other similar products
Theatres
Sport halls
Churches
Cinemas
Other
Sport halls
Churches
Cinemas
Other
INPUTS | ||||||||
Power | 230 V AC, 45-60 Hz, 150 Watt | |||||||
Passive protection Fuse 1,5 A | ||||||||
Surface coverage 1,000 sqm acc. to IEC 60118-4 | ||||||||
Slave LINE OUT 6.3 mm jack plug Induction loop monitoring 1 headphone output (left audio channel for induction loop output A and right audio channel for induction loop output B) |
||||||||
OUTPUTS | ||||||||
Loop Outputs | Max. current 2x 12 A RMS / 2x 33,9 A from peak to peak, 1-5 ms, 1 kHz Max. voltage 2x 31,1 V RMS / 2x 88 V peak to peak Output AGC Sets the voltage and current for continuous signals such as oscillation and sinus curves to -10 dB after 0.6-1 seconds. Short pulses and normal program signals are not limited. Frequency range 100 – 5.000 Hz (±3 dB) Distortion < 1 % Cable connection 2 screw terminals on the reverse of the device |
|||||||
Physical | Dimensions 90 x 430 x 270 mm (H x W x D), 19-inch rack (2 height units) Attachment 4 attachment points on the front plate for installation in 19-inch rack Colour black Weight 9,3 kg |
|||||||
Control and display | Loop setting Rotary knob for channel A and B Input level IN 1, IN 2 und IN3 can be set separately Display Main connection: 1 green LED Input level: 6 different coloured LEDs Current: 6 red LEDs per loop channel |
|||||||
Metal Loss Correction | Reduced sensitivity towards architecture-related steel reinforcements | |||||||
Inputs | IN 1 XLR(F) socket, Microphone input MIC sensitivity 2.5 mV – 10 V RMS IN 2 XLR(F) socket, can be switched as a microphone or line input IN 3 6.3 mm jack plug 100-V priority input for connection to PA systems |
|||||||